Cartridge Heaters for Hot Runners and Nozzles
Hot runner and nozzle cartridge heaters in 6.5 mm and 8 mm diameters with tip-sensitive thermocouples, swaged construction and tight diameter tolerance.
View details
Hot runner and nozzle cartridge heaters in 6.5 mm and 8 mm diameters with tip-sensitive thermocouples, swaged construction and tight diameter tolerance.
Give us the machine model, tonnage or the space it has to fit. We confirm the exact unit, controls and options before quoting.
Engineering review Monday to Saturday. Send the machine model and the output you need — the reply carries price, scope and delivery.
Not sure which size fits? Send the machine model or a photo of the existing unit and we will match it.
Hot runner heaters are a category of their own. They have to fit a bore that is often under 10 mm, respond fast enough to hold melt temperature shot to shot, and survive being pulled and refitted every time a tip is changed.
| Parameter | Range |
|---|---|
| Diameter | 6.0, 6.5, 8.0, 10 mm standard |
| Length | 40 - 250 mm |
| Power | 100 - 500 W |
| Watt density | 15 - 25 W/cm² |
| Sheath | 316L stainless, swaged |
| Thermocouple | Type J or K, tip sensitive, grounded or ungrounded |
| Lead | 300 - 1000 mm, stainless braid or fiberglass sleeve |
| Connector | Standard 2-pin or 4-pin plug to suit common controllers |
Diameter tolerance is the first. A hot runner bore is reamed to H7 and the heater is expected to slide in with light finger pressure but still make full contact; a nominal 6.5 mm element that measures 6.42 mm will run hot at the tip and cold at the base. We hold -0.02 / -0.05 mm on request and mark the actual size on the body.
Second is thermocouple placement. A tip-sensitive sensor reads the melt where it matters and reacts within a couple of seconds; a sensor buried at the lead end reads the manifold instead and lets the tip run cold. Third is the connector: match it to the controller you already own rather than changing plugs across the shop.
For the control side, see hot runner control systems. For general mold heating, the standard cartridge range covers most cavities.
Hot runner and nozzle cartridge heaters in 6.5 mm and 8 mm diameters with tip-sensitive thermocouples, swaged construction and tight diameter tolerance.
View detailsSend the machine model and the resin. We confirm geometry, material and surface treatment before quoting.
Have a drawing? Reply to our confirmation email with the file attached — PDF, STEP, DXF or a photo of the part all work.
Our engineering team answers during working hours, Monday to Saturday. For urgent orders, call +8613751260808.