Dongguan International Technology Transfer Center, 124 Dongbao Road, Dongcheng District, Dongguan, China
Request a quote
Hot Runner Temperature Control Systems
Hot Runner Control Systems

Hot Runner Temperature Control Systems

Hot runner temperature controllers from 1 to 48 zones with PID autotuning, soft start, zone alarms and thermocouple break detection.

Sourced to the machine you actually run

Give us the machine model, tonnage or the space it has to fit. We confirm the exact unit, controls and options before quoting.

Quoted to confirmed specs

Engineering review Monday to Saturday. Send the machine model and the output you need — the reply carries price, scope and delivery.

Email engineering

Not sure which size fits? Send the machine model or a photo of the existing unit and we will match it.

Details

Specification & application

A hot runner lives or dies on temperature control. A zone that overshoots on start-up carbonises the resin; a zone that reads the wrong thermocouple runs cold and produces short shots that look like a pressure problem.

System options

ParameterRange
Zones1, 2, 4, 8, 12, 24, 48 zone cabinets
InputType J or K thermocouple, grounded or ungrounded
OutputTriac or relay, 15 A per zone typical
ControlPID with autotune, manual override per zone
Accuracy±1 °C steady state
FeaturesSoft start, boost, standby, zone alarm, TC break detection
CommsOptional RS485 / Ethernet to machine HMI

What to look for

  • Soft start limits output until moisture is driven out of the heater — the single biggest life extender for hot runner heaters
  • Thermocouple break detection stops a zone running open loop at full power
  • Per zone current display lets a setter spot a failing heater before it takes a drop down
  • Standby mode drops zones to a holding temperature during breaks instead of cycling fully off
  • Labelled connectors matched to your existing hot runner cartridge heaters

We size cabinets to the manifold, not to a catalogue page: tell us the number of drops, the heater wattage per zone, the thermocouple type and the connector you already use.

Related

Other components in this range

View category

Need this part matched to your press?

Send the machine model and the resin. We confirm geometry, material and surface treatment before quoting.

Hot Runner Temperature Control Systems Quoted to confirmed specs